Intervallo di frequenza: 9KHz ~ 1.6GHz.
Gamma del generatore di tracciamento: 5MHZ ~ 1,6 GHz TG.
Sensibilità ottimale: -161dBm.
RBW: da 10 Hz a 1 MHz.
Design portatile, resistente e duraturo.
Può essere utilizzato sia in laboratorio che in campo.
Batteria al litio ad alta capacità integrata, può funzionare per più di 4 ore.
Comunicazione USB / LAN, facile per il controllo remoto.
Evidenzia schermo a colori di 5,6 pollici, risoluzione 640 * 480, visualizzazione chiara delle forme d'onda.
Features
HSA2000 Series measurement application:
Parameters |
|||
Model |
HSA2016A |
HSA2016B |
|
Frequency |
|||
Frequency Range |
9KHz~1.6GHz AC Coupled |
9KHz~1.6GHz AC Coupled 5MHZ~1.6GHz TG |
|
Frequency Resolution |
1Hz |
||
Reference Frequency |
10MHz |
||
Frequency Readout Accuracy |
±(frequency indication*frequency reference uncertainty+1%*span+20%RBW+marker resolution+1Hz) |
||
Internal 10MHz Reference Accuracy |
Aging rate |
±1ppm/year ( 0 ℃ ~50 ℃ , Reference is 25 ℃ ) |
|
Temperature stability |
±1ppm/year |
||
Marker Resolution |
(Frequency span)/(number of sweep points-1) |
||
Resolution Bandwidth ( RBW ) |
|||
-3dB Bandwidth |
10Hz to 1MHz , 1-3-10 sequence |
||
Accuracy |
±5% RBW=10Hz~1MHz nominal |
||
Resolution Filter Shape Factor |
< 5:1 nominal |
||
Video Bandwidth ( VBW ) |
-3dB bandwidth |
1Hz to 1MHz , 1-3-10 sequence |
|
Accuracy |
±10% VBM=1Hz~1MHz nominal |
||
Displayed Average Noise Level (normalized to1Hz) |
|||
9K~1MHz |
Preamp off |
-108dBm , typical -127dBm |
|
1MHz ~10MHz |
-128dBm , typical -146dBm |
||
10MHz ~500MHz |
-142dBm , typical -146dBm |
||
500MHz ~2.5GHz |
-141dBm , typical -145dBm |
||
2.5GHz ~3GHz |
-140dBm , typical -144dBm |
||
9K~1MHz |
Preamp on |
-131dBm , typical -150dBm |
|
1MHz ~10MHz |
-148dBm , typical -163dBm |
||
10MHz ~500MHz |
-161dBm , typical -164dBm |
||
500MHz ~2.5GHz |
-159dBm , typical -162dBm |
||
2.5GHz ~3GHz |
-158dBm , typical -161dBm |
||
SSB Phase Noise |
|||
Carrier Offset(20 ℃ ~ 30 ℃, 500MHz Central Frequency ) |
10K |
< -92 dBc/Hz, typical -95 dBc/Hz |
|
30K |
< -93 dBc/Hz, typical -96 dBc/Hz |
||
100K |
< -95 dBc/Hz, typical -97 dBc/Hz |
||
1MHz |
< -117 dBc/Hz, typical -119 dBc/Hz |
||
Sweep Time |
|||
Range |
Span >100Hz |
2ms to 1000s |
|
Span=0Hz |
600ns to 200s |
||
Sweep Mode |
Continuous, single |
||
Trigger Source |
Free run; video; external |
||
Trigger slope |
Selectable positive or negative edge |
||
Trigger delay |
Span =0Hz |
±12ms to ±12s nominal |
|
Frequency Counter |
|||
Counter Resolution |
1Hz |
||
Accuracy |
± (marker frequency × frequency reference uncertainty + counter resolution) |
||
Level Display Range |
|||
Log Scale and Units |
1 to 10 dB/divisions in 1, 2, 5, 10 dB steps, 10 divisions displayed |
||
Linear Scale and Units |
0 to 100% , 10 divisions displayed |
||
Scale Unit |
dBm , dBmV,dBuV,Watts , Volts |
||
Sweep (Trace) Points |
461 |
||
Number of Markers |
4 |
||
Detectors |
Normal, positive peak, dample, negative peak, RMS |
||
Number of Traces |
4 |
||
Trace Functions |
Clear/write, maximum hold, minimum hold, average, check , close |
||
Level Measurement Error |
± 1.5dB(excluding input VSWR mismatch) 20~30 ℃, peak detector, preamplifier off, input signal -50dBm to 0dBm |
||
Reference Level |
|||
Setting Range |
-100dBm to +30dBm, steps of 1dB |
||
Setting Resolution |
Log scale |
0.01dB |
|
Linear scale |
Almost log ( 2.236μV to 7.07V ) |
||
Amplitude |
|||
Maximum Safety Input Level |
Average continuous power |
+33dBm |
|
DC input voltage |
50Vdc |
||
Measurement Range |
9KHz~2MHz |
Displayed average noise level (DANL) to +10dB |
|
2MHz~3GHz |
Displayed average noise level (DANL) to +20dB |
||
Input attenuator range |
0 to 51dB,1dB steps |
||
Spurious Response |
|||
Second Harmonic Distortion ( SHI ) |
<65dBc , 50MHz to 3GHz ( Mixer level -30dBm , attenuator =0dB , preamp off , 20 ℃ ~30 ℃ ) |
||
Third-Order Intermodulation ( TOI ) |
50~300MHz |
+8dBm , Third-order intermodulation products : 2 x -20dBm; frequency separation 100KHz : attenuation = 0dB; preamp off , 20 ℃ ~30 ℃ |
|
300MHz~1.6GHz |
+10dBm |
||
Input Related Spurious |
<-75dBc , (input mixer = -30dBm) |
||
Inherent Residual Response |
<-90dBm , typical -98dBm (Input terminated and 0 dB RF attenuation, preamplifier off) |
||
RF Input VSWR (at Tuned Frequency) |
10MHz to 1.6GHz |
< 1.5:1, nominal Attenuator setting 10~20dB |
|
10MHz Reference/External Trigger Input |
|||
Reference Iinput Frequency |
10MHz |
||
Reference Input Amplitude |
0~10dBm |
||
Trigger Voltage |
5V TTL level |
||
Connector and Output Impendence |
N female ;( 50Ω ) |
||
Gennral Feature |
|||
Interface Language |
English , Chinese , Chinese Traditional |
||
Display Index |
5.7 inch , 640*480 resolution , 64M color LCD display |
||
Temperature Range |
Working |
-10 ℃ to +50 ℃ ,( battery : 0 ℃ to 50 ℃ ) |
|
Storage |
-40 ℃ to +70 ℃ ,( battery :-20 ℃ to 50 ℃ ) |
||
Relative Humidity |
<95% |
||
Weight |
2.9kg ( with battery ), 2.6kg ( without battery ) |
||
Size |
260m X 220m X 75m |
||
Power |
Input voltage range |
DC: 12-17V, maximum 2.8A input 220VAC±15% |
|
AC frequency range |
40Hz to 60Hz |
||
Power consumption |
Maximum 32W |
||